Für eine deutsche Übersetzung Klicken Sie hier
For more information about the product follow the respective links:
Precautions
- Do not remove the product label as it contains important information.
- Do not paint the detector.
Join to Network
- Detach the cover of the detector by twisting it counter clockwise.
- Insert one CR123A battery respecting the polarities.
- Put the plastic disc back (it fits only one way) and close the casing by twisting it clockwise.
- The Water Leak Detector will start searching (up to 15 minutes) for a Zigbee network to join.
- Make sure that the Zigbee network is open for joining devices and will accept the Water Leak Detector.
- While the Water Leak Detector is searching for a Zigbee network to join, the LED flashes red.
- When the LED stops flashing, the Water Leak Detector has successfully joined the Zigbee network.
Placement
- Place the alarm indoors at a temperature between 0-50°C.
- The Flood Sensor should be placed on the ground, where water is suspected
- Reachable for the battery testing and maintenance.
Testing
- Always test the working order of the Water Leak Detector after installation or battery change.
- When pressing the test button (closest to the battery), the alarm sound should be heard.
- A network alarm test can be performed by holding down the test button for at least 6.5 seconds (count 3 sounds).
- A test message will be sent over the Zigbee network.
Installation of the probe
NOTE: The Water Leak Detector Probe is an additional option for the Water Leak Detector. It is only included on request.
- Detach the detector from the probe base.
- Install the probe base on a wall by using enclosed screws.
NOTE: Make sure that the probe reaches required level either to the floor or down the drain. - The detector can be attached to the base simply by pushing it in there and rotating until it you hear a click.
Reset your device
Resetting is needed if you want to connect your Water Leak Detector to another gateway or if you need to perform a factory reset to eliminate abnormal behavior.
Steps for reseting
- Detach the cover of the detector by twisting it counter clockwise.
- Remove the plastic disc.
- Press and hold the LED button.
- While you are holding the button down, the LED first flashes once, then two times in a row, and finally numerous times in a row.
- Release the button while the LED is flashing numerous times in a row.
- After you release the button, the LED shows one long flash, and the reset is completed.
Modes
- SEARCHING GATEWAY MODE - The red LED inside of the device is flashing every second (up to 15 minutes)
- NORMAL MODE - The internal LED flashes red every 45 seconds.
- ALARM MODE - The simultaneous flashing of the internal red LED and sounding of intermittent audible signal. When water is detected, the alarm will sound. Press the “button/top” of the detector to acknowledge and stop the siren. The following 10 minutes, it will block alarms.
- LOW BATTERY MODE - Simultaneous audible signals and LED flashes every 45 seconds means that the battery should be replaced.
Fault finding
- If the Water Leak Detector does not work when the LED reset button is pushed, the probable cause is a faulty battery. Replace the battery if it is worn out.
- In case of a bad or weak signal, change the location of the Water Leak Detector. Otherwise, relocate your gateway or strengthen the signal with a smart plug.
- If the search for a gateway has timed out, a short press on the LED button will restart it.
Battery replacement
- To replace the battery, detach the cover of the Water Leak Detector by twisting it counter clockwise.
- Remove the plastic disc and replace the battery respecting the polarities. The Water Leak Detector uses 1xCR123 battery.
- Put the plastic disc back and close the casing by twisting it clockwise
Specifications
- Dimensions: Ø 60 x 37 mm
- Probe Dimensions: Ø 50 x 8,5 mm
- Cable length: 900 mm
- Color: White
- Battery: 1 x CR123A, exchangeable
- Battery life: 5 years, reporting every 5 minutes
- IP class: IP20
- Operation temperature: 0 to +50°C
- Relative humidity: up to 95% non-condensing
- Range: Minimum 100 meters (open field)
- Siren output: 85 dB/3m
- Temperature sensor: Range: 0 to +50°C
- Resolution: 0.1°C (accuracy ± 0.5°C)
- Wireless protocol: Zigbee 3.0