Für eine deutsche Übersetzung Klicken Sie hier


For more information about the product follow the respective links:



Precautions

  • Do not remove the product label as it contains important information.
  • Do not paint the alarm.
  • Avoid placing the Intelligent Smoke Alarm in dusty rooms.
  • Do not place the alarm in a kitchen, garage, or in other places where damp, gases and smoke naturally occur.


Join to Network

  1. Pull out the battery isolation strip as shown.
  2. The Intelligent Smoke Alarm will now start searching (up to 15 minutes) for a Zigbee network to join.
  3. Make sure that the Zigbee network is open for joining devices and will accept the Intelligent Smoke Alarm. 
  4. While the Intelligent Smoke Alarm is searching for a Zigbee network to join, the LED button flashes red.
  5. When the LED button stops flashing, the Intelligent Smoke Alarm has successfully joined the Zigbee network.


Placement

  • Place the Intelligent Smoke Alarm indoors at a temperature between 0-50*C. 
  • It is important to place Intelligent Smoke Alarms in bedrooms and on exit routes. 
  • The distance between the Intelligent Smoke Alarm and walls, ventilation, or other obstacles, should be at least 50 cm.
  • The distance between the alarm and a fireplace or stove should be at least 4 meters
  • Rooms larger than 80 m2 require several Intelligent Smoke Alarms in order to sustain full fire safety.
  • The alarm should be placed within reach for battery testing and maintenance. 
  • The alarm should not be placed at the top of high pointed ceilings or in-ceiling corners or within 50 cm of a wall.

  

  • Placement examples
  • Recommendes locations
  • Ceiling placement
    • The Intelligent Smoke Alarm should be a minimum of 50 cm from the wall.
  • Wall placement
    • The Intelligent Smoke Alarm should be between 30 and 50 cm from the ceiling.
    • There should be at least one Intelligent Smoke Alarm per floor and a maximum distance between Intelligent Smoke Alarms of 10 meters.

Mounting


  1. Detach the alarm from the mounting base by twisting counterclockwise. 
  2. Use the mounting base ring to mark the screw holes on the ceiling or on the wall.
  3. Use enclosed screws and plugs to install the mounting base in the marked position.
  4. If the battery is missing or inserted incorrectly, it will be impossible to attach the alarm in the mounting base.
  5. Attach the alarm by twisting clockwise until it clicks.


Testing


  1. Always test the working order of the Intelligent Smoke Alarm after installation or battery change.
  2. When pressing the alarm button, the alarm sound should be heard.


Modes

  • LOW BATTERY MODE - Simultaneous audible signals and front LED flashes every 45 seconds means that the

    battery should be replaced.

  • REPLACE DEVICE MODE -  When audible signals and front LED flashes are not simultaneous, the device should be replaced. The life expectancy of Intelligent Smoke Alarms is generally 10 years, after which their sensors begin to lose sensitivity.


Reset the Device


Resetting is needed if you want to connectyour Intelligent Smoke Alarm to another gateway or if you need to perform a factory reset to eliminate abnormal behavior.

  1. Detach the alarm from the mounting base by twisting it counter-clockwise.
  2. Press and hold the LED button. 
  3. While you are holding the button down, the LED first flashes once, then two times in a row, and finally numerous times in a row.
  4. Release the button while the LED is flashing numerous times in a row. 
  5. After you release the button, the LED shows one long flash, and the reset is complete



Fault finding & cleaning

  • Dust particles in the smoke chamber can be removed by vacuuming the mesh.
  • High humidity condensing can be resolved by drying the Intelligent Smoke Alarm. 
  • If the Intelligent Smoke Alarm does not work when the test button is pushed, the probable cause is a faulty battery. Replace the battery if it is worn out. 
  • In case of a bad or weak signal, change the location of the Intelligent Smoke Alarm.
  • Otherwise, you can relocate your gateway or strengthen the signal with a smart plug. 

  • If the search for a gateway has timed out, a short press on the LED button will restart it.


Battery replacement


CAUTION: RISK OF EXPLOSION IF BATTERIES ARE REPLACED BY AN INCORRECT TYPE. DISPOSE OF THE BATTERIES IN ACCORDANCE WITH INSTRUCTIONS.

CAUTION: When removing cover for battery change - Electrostatic Discharge (ESD) can harm electronic components inside.

  1. To replace the battery, detach the Intelligent Smoke Alarm from the mounting base by twisting counter-clockwise.
  2. Replace the battery respecting the polarities. The Intelligent Smoke Alarm uses 1xCR123 battery.
  3. Attach the alarm in the mounting base by twisting clockwise until it clicks, and test the alarm.


Specifications


  • Dimensions: Ø 60 x 40 mm
  • Color: White
  • Battery: 1 x CR123A, exchangeable
  • Battery life: 3 years, reporting every 5 minutes
  • IP class: IP20
  • Operation temperature: 0 to +50°C
  • Relative humidity: 10% to 95% non-condensing
  • Siren output: 85 dB/3m
  • Temperature sensor: Range: 0 to +50°C
  • Resolution: 0.1°C (accuracy ± 0.5°C)
  • Wireless protocol: Zigbee 3.0