Installation
DANGER OF ELECTROCUTION BEFORE ANY INSTALLATION MAKE SURE THE POWER SUPPLY IS DISCONNECTED TO AVOID ANY RISK OF ELECTROCUTION. Directly cut the power supply from the breaker box to avoid any risk of electrocution. This relay switch is designed to be used power-up, a wrong installation can create a fire or an electric shock. If you are not confident about electrical installation, please ask a professional. The relay switch must be installed and connected carefully following the instructions of this user guide. We will not be responsible for any loss or damage resulting from a non-respect of the instructions of this user guide. Cut the power supply before any operation and don’t do any modification if the LED is still ON.
Terminal description
Wiring - with energy measurement
- Cut the power supply
- Dismantle the wired switch controlling the light(s) you want to connect.
- Install the Multifunction Relay Switch according to the diagram.
- Reinstall the wired switch.
- Turn the power supply back ON.
AUTO-DETECTION OF SWITCH TYPE
When you turn the power supply ON (via the electrical box for example) once the relay switch is installed, it is necessary to perform a simple action (single press on the button) on the wired switch(es). Automatic detection of the type of switch (monostable or bistable) will then be performed.
Wiring - without energy measurement
- Cut the power supply
- Dismantle the wired switch controlling the light(s) you want to connect.
- Install the Multifunction Relay Switch according to the diagram.
- Reinstall the wired switch.
- Turn the power supply back ON.
Wiring - Potential-free without energy measurement - Pulse mode
- Cut the power supply
- Dismantle the wired switch controlling the light(s) you want to connect.
- Install the Multifunction Relay Switch according to the diagram.
- Reinstall the wired switch.
- Turn the power supply back ON.
Pulse mode
It is imperative to activate the impulse mode before pairing your module to your home automation gateway to control your gate/garage door/electric latch to avoid damaging your equipment.
- Do 5 brief presses on the button of the relay switch. The LED pulses in green, confirming the activation of the control access mode.
- Note: To deactivate the impulse mode, repeat a series of 5 short presses.
Join to Zigbee Network
- When power is turned ON, the relay switch LED will blink orange, looking to join a Zigbee network. Go to your Zigbee gateway app to activate the relay switch detection.
- If the relay switch has correctly joined the network, the LED becomes green. The relay switch is ready for use.
- If the relay switch hasn’t joined a network within 15 minutes, the LED becomes orange. Do a brief press on the relay switch button and start again.
Reset & Remove from Zigbee Network
- Press more than 5 seconds on your module’s button. The LED blinks orange.
- Press the button again (short press) to validate the reset. If the reset is successful, the LED flashes red and green alternately, then flashes orange. Repeat if necessary.
- Your module has returned to its original configuration and is ready to join a new Zigbee network.
Technical data:
- Power supply: 230V AC ~ 50Hz
- Switching capacity: 230V AC – 14A
- Own consumption: <1W
- Maximum output power: 3.000W – Integrated zero crossing
- Radio protocol: Zigbee 3.0
- Radio frequency: 2,4 GHz
- Maximum transmission power: +10dBm
- Reach: bis zu 40m
- Operating temperature:
The SIN withstands ambient temperatures:
• Between -20 and 40° in the fresh air.
• Between -20 and 35°C in the wall box.
• Between -20 and 40°C in the NodOn DRB (Din Rail Box).
• Between -20 and 40°C in the NodOn BPS (Aufputzdose). - Protection class: IP 20