I/O Module - FRIZIOMZB-110

Modified on Tue, 5 Sep, 2023 at 8:55 AM

Für eine deutsche Übersetzung Klicken Sie hier


For more information about the product, follow the respective links:



Precautions  

  • WARNING: For safety reasons, always disconnect power from the IO module, before connecting wires to inputs and outputs.

  • Do not remove the product label, as it contains important information.

  • Do not open the IO Module.

  • Do not paint the device.


Join your Network


  1. When the device is connected and powered up, the IO Module will start searching (up to 15 minutes) for a Zigbee network to join. While the IO Module is searching for a Zigbee network to join, the yellow LED flashes.
  2. Make sure that the Zigbee network is open for joining devices and will accept the IO Module.
  3. When the LED stops flashing, the device has successfully joined the Zigbee network.
  4. If the scanning has timed out, a short press on the reset button will restart it.

Placement  

  • Connect the IO Module to a device that is located at a temperature between 0-50°C.


Connecting to wired device


You can connect the IO Module to different wired devices: doorbells, window blinds, wired security devices, heat pumps and more. The connection of the different devices follows the same principle, using the different inputs and outputs:


IN1

IN2

IN3

IN4


NC2

COM2
NO2
NC1
COM1
NO1
5-28 V d.c.

USB PWR

RST
LED
Inputs with internal Pull Up. Must be shorted to IO Module GND for signal IO Module GND



Normally Closed for Relay Output 2
Common for Relay Output 2
Normally Open for Relay Output 2
Normally Closed for Relay Output 1
Common for Relay Output 1
Normally Open for Relay Output 1

Power Supply

NOTE: Use ”5-28 V” or ”USB PWR”. If both are connected ”5-28V” is the primary Power Supply.

Power Supply

NOTE: USB PWR is then used as fall back in case ”5-28 V” is disconnected.

Reset

User Feedback


Reset your device 


  1. Connect the IO Module to a power outlet.
  2. Press and hold the reset button with a pen
  3. While you are holding the button down, the yellow LED first flashes once, then two times in a row, and finally numerous times in a row.
  4. Release the button while the LED is flashing numerous times in a row.
  5. After you release the button, the LED shows one long flash, and the reset is completed.


Modes 


  • SEARCHING GATEWAY MODE - The yellow LED flashes.


Fault finding 


  • In case of a bad or weak wireless signal, change the location of the IO Module. Otherwise, you can relocate your gateway or strengthen the signal with a range extender.

  • If the search for a gateway has timed out, a short press on the button will restart it.


Specifications 


  • Frequency: Zigbee 3.0
  • Dimensions (W xD x H):  45 x 16 x 45 mm
  • Color: White
  • Power supply: 6 - 28V DC or USB 
  • Power consumption: 0.3 W
  • Operation temperature: 0 to +50°C
  • Relative humidity: 5% - 95%, non condensing
  • IP class: IP20
  • Output:
    • 2 pcs NO/NC - on/off or pulse
    • Max switch voltage: 30V
    • Max Switch Current: 1A
  • Input:
    • 4 pcs contact input (potential free switch or relay) NO/NC by SW
    • Each input can be configured as an IAS alarm




Was this article helpful?

That’s Great!

Thank you for your feedback

Sorry! We couldn't be helpful

Thank you for your feedback

Let us know how can we improve this article!

Select at least one of the reasons

Feedback sent

We appreciate your effort and will try to fix the article